Mighty Mule FM502 User Manual (2024)

Mighty Mule FM502 User Manual (1)

1. KEEP CLEAR! Gate may move at any time.

2. Do not allow children to operate gate or play in gate area.

3. This gate is for vehicles only. Pedestrians must use separate entrance.

WARNING

!

MOVING GATE

Can Cause Injury or Death

UL325 SERIES

50

2

®

E-Z GATE OPENER

1-800-543-GATE (4283) • www.mightymule.com

1. KEEP CLEAR! Gate may move at any time.

2. Do not allow children to operate gate or play in gate area.

3. This gate is for vehicles only. Pedestrians must use separate entrance.

WARNING

!

MOVING GATE

Can Cause Injury or Death

UL325 SERIES

50

2

®

E-Z GATE OPENER

1-800-543-GATE (4283) • www.mightymule.com

UL325 SERIES

502

®

E-Z GATE OPENER

DUAL GATE SYSTEM

©

2002 GTO, Inc.

WARNING!

This equipment is similar to other gate or door equipment and meets or exceeds

Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has

hazards associated with its use and therefore by installing this product the installer

and user accept full responsibility for following and noting the installation and

safety instructions. Failure to follow installation and safety instructions can result

in hazards developing due to improper assembly. You agree to properly install this

product and that if you fail to do so GTO, Inc. shall in no event be liable for direct,

indirect, incidental, special or consequential damages or loss of profi ts whether

based in contract tort or any other legal theory during the course of the warranty

or at any time thereafter. The installer and/or user agree to assume responsibility

for all liability and use of this product releasing GTO, Inc. from any and all

liability. If you are not in agreement with this disclaimer or do not feel capable

of properly following all installation and safety instructions you may return this

product for full replacement value.

READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before

attempting to install and use this automatic gate opener. This gate opener

produces a high level of force. Stay clear of the unit while it is operating and

exercise caution at all times.

All automatic gate openers are intended for use on vehicular gates only.

This product meets and exceeds the requirements of UL 325, the standard which regulates gate opener safety,

as established and made effective March 1, 2000, by Underwriters Laboratories Inc.

3121 Hartsfi eld Road • Tallahassee, Florida, USA 32303

Telephone GTO Sales: 1-800-543-GATE (4283) or (850) 575-0176 • Fax (850) 575-8912

or GTO Technical Service: 1-800-543-1236 or (850) 575-4144 • Fax (850)575-8950

www.mightymule.com

L

I

S

T

E

D

US

Mighty Mule FM502 User Manual (2)

VEHICULAR GATE OPENER CLASS CATEGORIES

Residential Vehicular Gate Opener-Class I

hotel, garages, retail store, or other building servicing the general public.

use in an industrial location or building such as a factory or loading dock area or other locations not intended to

____________________

____________________

Remember to keep all receipts for

proof of purchase.

kilograms 2.2046 pounds lb. (or #)

pounds 0.4535 kilograms kg

Mighty Mule FM502 User Manual (3)

-------------------------------------------------------------

--------------------------------------------------

Disconnecting the Opener

-------------------------------------------------------------

page 1

Important Safety Instructions for the Consumer

page 2

Secondary Means of Protection Against Entrapment

------------------------------

page 5

Required Safety Precautions for Gates

-----------------------------------------------

page 6

Warning Signs and Labels

page 7

--------------------------------------------------------------------------

Parts List

---------------------------------------------------------------------------------

page 8

Technical Specifi cations

page 10

Installation of the Mounting Hardware

----------------------------------------------

page 12

Mounting the First Opener

page 16

Installing the Second Opener

----------------------------------------------------------

page 16

Installation of the Closed Position Stops

--------------------------------------------

page 17

Mounting the Control Box

page 19

Connecting the Opener Power Cables

-----------------------------------------------

page 20

--------------------------------------------------------------

Solar Chart

page 21

Connecting the Transformer

-----------------------------------------------------------

page 21

----------------------------------------------------------

Obstruction Sensitivity

page 25

Main DIP Switches

page 26

Dual Mode DIP Switches

--------------------------------------------------------------

page 27

Setting Closed Position Limits

--------------------------------------------------------

page 28

-------------------------------------

----------------------------------------

----------------------------------------------------------

Setting Open Position Limits

----------------------------------------------------------

page 33

--------------------------------------

--------------------------------------------------

Accessory Catalog

----------------------------------------------------------------

Table of Contents

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

Mighty Mule FM502 User Manual (4)

Mighty Mule® E-Z Gate® Opener

—GTO's "do-it-yourself" automatic gate opener!

When correctly installed and properly used, your

Mighty Mule® E-Z Gate® Opener

will give you many years

Mighty Mule® E-Z Gate® Opener

Mighty Mule® E-Z Gate® Opener

pull-to-open dual leaf gate

the property). By purchasing an

Mighty Mule® E-Z Gate® Opener

from the property). The gate must not exceed 18 feet in length and

on page 10). The

Mighty Mule® E-Z Gate® Opener

can be used on vinyl, aluminum, chain

high resistance to the wind. If the wind is strong enough, the opener will obstruct and stop.

Mighty Mule® E-Z Gate® Opener

accommodates extra transmitters, digital keypads, solar panels, push buttons,

Mighty Mule®

Accessory Catalog

Mighty Mule® E-Z Gate® Opener

features

adjustable obstruction sensing.

MIN

is the factory setting;

Mighty Mule® E-Z Gate® Opener

also has an

adjustable auto-close feature

button at any time after the gate opens fully will cause it to close immediately.

Swing gates longer than 18 feet or weighing more than 850 pounds;

Slide gates;

Heavy duty or commercial uses;

Professional installation;

please call GTO at

(850) 575-0176

for information about our

professional

dealer near you.

E-Z GATE OPENERS

®

®

carefully and completely

to become familiar with all parts and installation steps. The video tape is only designed as

Mighty Mule FM502 User Manual (5)

Keep in mind that the gate opener is just

one component of the total gate operating system

that can result in damage to the opener or its components, serious

only

part

of the total gate operating system, it is the responsibility of the

Substitute a

Pin Lock

for the clevis pin on the front

the opener from the gate (

Clevis Pin

Hairpin Clip

Gate Bracket

Front or Rear Mount

Bushing

Mighty Mule FM502 User Manual (6)

1.

Failure to meet the requirements set forth in the instruction

2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed

3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when

open into public access areas.

4. The gate and gate opener installation

1. Verify this dual opener is proper for the type and size of gate, its frequency of use and the proper class rating.

2. Make sure the dual gate has been properly installed and swings freely in both directions. Repair or replace all worn

3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the

4. This gate opener is intended for

use (

5. Always keep people and objects away from the gate and its area of travel.

6. Pay close attention to the diagram below and be aware of these areas at all times.

Gate in the  Open Position

Gate in the  Open Position

ZONE 2

ZONE 3

ZONE

4

ZONE

5

Driveway

ZONE 1

ZONE 2

ZONE 4

ZONE 5

ZONE 3

Mighty Mule FM502 User Manual (7)

Entrapment Zones for a proper Pull-To-Open installation:

Zone 1 – leading edge of the gate and the fence post.

Zone 2 – between the gate and the gate post.

Zone 3 – the path of the gate.

Zone 4 – the space between the gate in the open position and any object such as a wall, fence, tree, etc.

Zone 5 – pinch points between the opener and gate or post.

1. Install the gate opener on the inside of the property and fence line.

install an opener on the outside of the

2. Be careful with moving parts and avoid close proximity to areas where fi ngers or hands could be pinched.

3. Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide additional protection

4. If push buttons or key switches are installed, they should be within sight of the gate, yet located at least 10 feet from

Never install any control device where a user will be tempted to

reach through the gate to activate the gate opener.

5. Do not activate your gate opener unless you can see it and can determine that its area of travel is clear of people,

pets, or other obstructions. Watch the gate through its entire movement.

6. Secure outdoor or easily accessed gate opener controls in order to prohibit unauthorized use of the gate.

Moving Gate

Area

Moving Gate

Area

Driveway

10'10'

10'10'

10'10'

NEVER INSTALL

any control device

within gray area

Mighty Mule FM502 User Manual (8)

1. Attach the

(

your responsibility

to post warning signs on both sides of your gate. If any of these signs or warning decals become

2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact

3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.

4. Do not attempt to "beat the gate" while the gate is closing. This is extremely dangerous.

5. Do not allow children or pets near your gate.

Never let children operate or play with gate controls

remote controls away from children and unauthorized users; store controls where children and unauthorized users do

6.

7. Service the gate and gate opener regularly. Grease hinges, and replace the battery every 3-5 years.

8. To operate this equipment safely, YOU must know how to disconnect the opener for manual gate operation

(

9. Disconnect the opener

when the power is

and the gate is

moving.

10. Make arrangements with local fi re and law enforcement for emergency access.

11. Distribute and discuss copies of the

section of this manual with all

persons authorized to use your gate.

12.

Should you lose or misplace this manual, a copy can be obtained by

Mighty Mule FM502 User Manual (9)

Secondary Means of Protection Against

As specifi ed by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate openers shall have an inherent entrapment

provisions for

primary

type of entrapment protection. Also, the Mighty Mule® has

provisions for

the connection of

protection to be used

secondary

type of entrapment protection, if desired.

A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and

outside of a vehicular swing gate system.

B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the

sensor and the gate opener is not subjected to mechanical damage.

C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate opener for entrapment

protection functions shall be located where the transmission of the signals are not obstructed or impeded by building

structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended

end-use conditions.

twice

while opening or closing. This alarm will sound for a period of

keypads will not deactivate the alarm.

Bottom Edge Contact Sensor

on both sides of the gate

Leading Edge Contact Sensor

on both sides of the gate

Post Edge Contact Sensor

on both sides of the gate

Post Edge Contact Sensor

on both sides of the gate

Vehicular GateVehicular Gate

500

UL325 SERIES

®

E-Z GATE OPENER

1-800-543-GATE (4283)

www.mightymule.com

Mighty Mule FM502 User Manual (10)

may not be sensitive enough

to prevent bodily injury

in

some circ*mstances

reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment.

Warning Signs

be installed on both sides of the

alert people of automatic gate operation and are

when installing the Mighty Mule® E-Z Gate®

recommend using the

(

1. KEEP CLEAR! Gate may move at any time.

2. Do not allow children to operate gate or play in gate area.

3. This gate is for vehicles only. Pedestrians must use a separate entrance.

Moving Gate Can Cause

Injury Or Death

WARNING

!

Warning SignWarning Sign

Contact Sensor

(

recommended, not included

)

Contact Sensor

(

recommended, not included

)

Pedestrian Gate

Bulldog

Pedestrian

Gate L

ock

(recommended, not included

)

Vehicular GateVehicular Gate

Contact Sensor

(

recommended, not included

)

Contact Sensor

(

recommended, not included

)

Mighty Mule FM502 User Manual (11)

!

Warning signs (2 enclosed) to be installed on each side of the gate (3—5 feet above the bottom of the gate)

Maximum Gate: 500 lb. (226.7 kg); 16 ft. (4.8 m) Voltage: 12 Vdc; Frequency: 0 Hz; Power: 25

W Class I, II, III and IV Vehicular Swing Gate Operator. Serial Number: XXXXXXXXXX

#xxxxxxx

Conforms to UL 325 STANDARDS

TO MANUALLY OPEN AND CLOSE THE GATE:

1. Turn control box power switch OFF.

2. Disconnect front or rear mount from gate bracket

.

3. Pull opener away from front or rear mount.

DC SWING SERIES / 500

GTO, Inc. Tallahassee, Florida USA

Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving.

L

I

S

T

E

D

US

50

2

UL325 SERIES

®

®

E-Z GATE OPENER

Product identification and manual operation instruction label (1) installed on control box cover

Logo and warning labels (2) installed on each side of opener housing

C

Mighty Mule FM502 User Manual (12)



























 

 









 



®

E-Z GATE OPENER



1. KEEP CLEAR

! Ga

t

e

may move at any

t

ime.

2. Do n

ot allow children

to operate gate

or play in gate ar

ea.

3. This gat

e is for vehicles on

ly. Pedestrians must

use separat

e entrance.

WARNING

!

MOVING GATE

Can Cause In

jury or Death

UL325 SERIES

502

®

E-Z GATE OPENER

1-800-543-GATE

(4283) • www.mightymule.com

1. KEEP CLEAR!

Gate may move at

any time.

2. Do n

ot allow children to o

perate gate or play i

n

gate

area.

3. This gate

is

for v

ehicles only

. Pedestrians mus

t

use s

eparate entrance.

WARNING

!

MOVING GATE

Can Cause Injur

y or Death

UL325 SERIES

502

®

E-Z GATE OP

ENER

1-800-5

43-GATE (4283) •

www

.mightymul

e.com



Mighty Mule FM502 User Manual (13)

///

/

/

Transformer (1)

Battery (1)

Control Box (1)

Wa

rning Signs (4)

GT

O Transmitter(1)

1. KEEP CLEAR! Gate may move at any time.

2. Do not allow children to operate gate or play in gate area.

3. This gate is for vehicles only. Pedestrians must use a separate entrance.

Moving Gate Can Cause

Injury Or Death

WARNING

!

Receiver (1)

Accessory Catalog

page 39):

the transformer power supply and the control box. See

on page 21, and the

Accessory Catalog

power to trickle charge the battery. See the

Accessory Catalog

to mount the front of the

Mighty Mule FM502 User Manual (14)

DRIVE

NOTE: The transformer should not be

directly

with higher ampere rated fuses; doing so will void your warranty and may damage your control board.

/

/

GTO

microprocessor-based control board is set for single leaf, pull-to-open gate installations. DIP switches can be

/

4

tion of gate and installation.

MIGHTY MULE® 502 E-Z GATE® OPENER

"NR" indicates this

Mighty Mule 502.

page 19

or call

(800) 543-1236

or

for more information.

Gate Weight

Gate Length

Number of Cycles Per Day

Mighty Mule 502 Gate Capacity /Cycle Chart

Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.

850 lbs. 750 lbs. 650 lbs. 550 lbs. 450 lbs. 350 lbs. 250 lbs. 150 lbs. 100 lbs.

50 lbs.

68 73 78 83 88 93

98 103 108 113

5’ - 6’

63 68 73 78 83 88 93

98 103 108

8’

63 68 73 78 83 88 93 98

103

10’

63 68 73 78 83 88 93 98

12’

63 68 73 78 83 88 93

14’

63 68 73 78 83 88

16’

NR NR NR NR

NR

63 68 73 78 83

18’

NR NR NR NR

NR NR NR

NR NR

NR

NR = NOT RECOMMENDED

Mighty Mule FM502 User Manual (15) Loading...

Mighty Mule FM502 User Manual (2024)

FAQs

What does it mean when a mighty mule gate opener starts beeping on its own? ›

Your battery in your GTO, inc / Mighty Mule automatic driveway gate opener is running low. There can be a couple of causes. One is a possibility is dead cell in your battery in your GTO, inc / Mighty Mule automatic driveway gate opener. Another could be your battery is not getting electricity to charge it.

Why is my electric gate beeping and not opening? ›

The most common reason for beeping is that the battery of your automatic gate's motor is running low. This usually happens when the power source has been disconnected or if the battery is old and needs to be replaced.

Why does my gate keep opening by itself? ›

The most common reason though is always due to dirt, as well as insects or leaves that may build up. For these reasons and given that the selector can lead to random openings, it should be regarded as one of the first checks to perform in these circ*mstances.

Why does my mighty mule keypad beep 3 times? ›

If more than 10 seconds elapse between key presses, the keypad will beep 3 times and go into “idle” mode. Up to 25 Entry Codes may be programmed into the keypad. Temporary Entry Codes can be programmed to expire within one to seven (1–7) days.

How to reset gate code? ›

How To Reset A Wireless Keypad On a Gate
  1. Take off the panel from the keypad unit.
  2. Disconnect your battery.
  3. Hold the reset button, reconnect the battery, and then release the reset button.
  4. Press the star key three times and wait around 30 seconds.
  5. Place the front panel back on the keypad unit.

How do I reset my automatic gate opener? ›

Steps To Reset An Automatic Gate
  1. Step 1: Turn The Power Off. ...
  2. Step 2: Remove The Backup Battery. ...
  3. Step 3: Wait For A Few Minutes. ...
  4. Step 4: Inspect the Gates and Sensors. ...
  5. Step 5: Find The Reset Button. ...
  6. Step 6: Reattach The Backup Battery. ...
  7. Step 7: Turn on The Power. ...
  8. Step 8: Test & Adjust.

Why does my mighty mule gate open by itself? ›

The gears of the gate are sometimes the most common problem that can cause automatic gates to open by themselves. This is usually caused by wear and tear or lack of regular maintenance.

How do I make my Mighty Mule gate stay open? ›

You set the timer for self close time to off position. this lets the gate stay open till you click the remote again. If you want to have the gate be self closing most of the time but want it to stay open when you want then you have to open the gate with the remote then use the remote to begin to close it.

What is the master code for Mighty Mule gate opener? ›

Default master code is 1234. Open Collector Output: Used to connect Keypad to gate opener that accepts logic inputs (All GTO gate openers) in hard-wired applications.

How to program a remote gate opener? ›

Let's get your gate opening with this quick and handy step-by-step guide.
  1. Step 1: Locate the Learn Button. Most gate openers have a “Learn” or “Program” button on the main unit or the control panel. ...
  2. Step 2: Enter Programming Mode. ...
  3. Step 3: Program the Remote Control. ...
  4. Step 4: Test the Remote. ...
  5. Step 5: Exit Programming Mode.
Jan 29, 2024

Why does my security gate keep beeping? ›

Many automatic gates are equipped with backup batteries that ensure the gate can operate during a power outage. But when these batteries run low, the system will emit a beep to alert you. You can start by checking the battery levels using a multimeter. If the voltage is low, recharge the batteries if possible.

How long does a battery last on a Mighty Mule gate opener? ›

So no batteries are every recharged more than once a year. They only seem to last two years.

Top Articles
Latest Posts
Article information

Author: Lidia Grady

Last Updated:

Views: 6271

Rating: 4.4 / 5 (65 voted)

Reviews: 88% of readers found this page helpful

Author information

Name: Lidia Grady

Birthday: 1992-01-22

Address: Suite 493 356 Dale Fall, New Wanda, RI 52485

Phone: +29914464387516

Job: Customer Engineer

Hobby: Cryptography, Writing, Dowsing, Stand-up comedy, Calligraphy, Web surfing, Ghost hunting

Introduction: My name is Lidia Grady, I am a thankful, fine, glamorous, lucky, lively, pleasant, shiny person who loves writing and wants to share my knowledge and understanding with you.